11B145SL00380

THREE-POLE CONTACTOR, IEC OPERATING CURRENT IE (AC3) = 150A, AC/DC COIL, PREDISPOSED FOR MECHANICAL LATCH (G495), 380…415VAC/DC

Add to cart
Order code 11B145SL00380
Weight [g]5320
Qty. per package1
Multiple qty. of packs per order 1
Package dimensions [mm]173X124X194
Volume [cm³]4161.688
Bar code [EAN13]8013975047965
HS Code85365080
Dimensions
Certifications:
CCC
EAC
cULus
Conformity:
IEC/EN 60947-1
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
CSA C22.2 n° 60947-1
CSA C22.2 n° 60947-4-1
Data Sheet  | Download Data Sheet
Product type designation B145
Contact characteristics
Number of poles nr. 3
Rated insulation voltage Ui V 1000
Rated impulse withstand voltage Uimp kV 8
Operating frequency
Operational frequency min Hz 25
Operational frequency max Hz 400
Conventional free air thermal current Ith A 250
Operating current
Operational current AC3 (≤440V ≤55°C) A 150
Operational current AC4 (400V) A 57
Short-time allowable current for 10s (IEC/EN60947-1) A 1300
Protection fuse
gG (IEC) A 250
aM (IEC) A 160
Making capacity (RMS value) A 1500
Breaking capacity at voltage
Breaking capacity 440V A 1500
Breaking capacity 500V A 1400
Breaking capacity 690V A 1200
Resistance per pole (average value) mΩ 0.3
Power dissipation per pole (average value)
Power dissipation pole (average value) Ith W 14.5
AC3 W 6.8
Tightening torque for terminals
min Nm 18
max Nm 18
min Ibft 13.3
max Ibft 13.3
Tightening torque for coil terminal
min Nm 1
max Nm 1
min Ibft 0.74
max Ibft 0.74
Ambient conditions
Temperature
Operating temperature
min °C -50
max °C 70
Storage temperature
min °C -60
max °C 80
Max altitude m 3,000
Operating position
normal Vertical plan
allowable ±30°
Mounting Screw / DIN rail 35mm
Weight g 5.4
Operations
Mechanical life Cycles 10,000,000
Electrical life Cycles 1100000
Safety related data
Mirror contats according to IEC/EN 609474-4-1 Yes
EMC compatibility Yes
AC coil operating
Rated AC voltage at 50/60Hz, 60Hz
min V 24
max V 480
AC operating voltage
of 50/60Hz coil powered at 50Hz
pick-up
min %Us 80
max %Us 110
Dissipation at holding ≤20°C 50Hz W 10
DC coil operating
DC operating voltage
Average coil consuption ≤20°C
in-rush W 300
holding W 10
Max cycles frequency
Mechanical operations Cycles/h 3,600
Downloads
Catalogue
Document Icon
02 - Contactors
02 January 2018
EN
Brochures
Document Icon
Orange motor protection and control
PD053 March 2006
EN
Document Icon
Contactors for wind energy applications
PD066 May 2010
EN
Document Icon
Motor starting solutions
PD116 June 2016
EN
Technical instructions
Document Icon
Contactors
B115, B145, B180, B250, B310, B400, B500, B630, B630 1000

I010 April 2016
EN
Document Icon
Contactors
B1250, B1600

I035 October 2001
EN
 
2D drawings
Document Icon
11B145SL00380
2d_11B145SL00380
3D drawings
Document Icon
11B145SL00380
3d_11B145SL00380
Certifications
Document Icon
UE declarations
EU006-2016_1
EN
Document Icon
UL declaration
E93602
EN